Spectroscopy

Flame Photometer

BK-FP6410B / BK-FP6430B / BK-FP6431B / BK-FP6432B / BK-FP6440B / BK-FP6450B

Flame photometer for determining elements from the intensity of radiation emitted in a flame. It is used for routine analysis of water, soil, fertiliser, food and clinical samples; measurable elements vary by model.

Key features

  • Controlled optical measurement
  • Configurations for different spectral ranges
  • R&D and quality-control applications
Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery to the UK, all European countries, USA, Canada, Mexico and South America.

01 / Accessories

Available accessories

Included accessories

  • Oil-free air compressor
  • Regulator and tubing for LPG, air and waste liquid

Optional accessories

  • Atomiser or nebuliser
  • Printer
  • Compatible software

Final contents, accessory compatibility and availability are confirmed in the quotation for the selected model.

02 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterBK-FP6410BBK-FP6430BBK-FP6431BBK-FP6432BBK-FP6440BBK-FP6450B
Test ElementK/NaK/Na/LiK/Na/CaK/Na/BaK/Na/Li/CaK/Na/Li/Ca/Ba
Channel Qty.233345
LOD(ppm) — K≤0.156≤0.156≤0.156≤0.156≤0.156≤0.156
LOD(ppm) — Na≤0.184≤0.184≤0.184≤0.184≤0.184≤0.184
LOD(ppm) — Li—≤0.104——≤0.104≤0.104
LOD(ppm) — Ca——≤2.004—≤2.004≤2.004
LOD(ppm) — Ba———≤6.043—≤6.043
Linear Error(ppm) — K≤0.195≤0.195≤0.195≤0.195≤0.195≤0.195
Linear Error(ppm) — Na≤0.69≤0.69≤0.69≤0.69≤0.69≤0.69
Linear Error(ppm) — Li—≤0.146——≤0.146≤0.146
Linear Error(ppm) — Ca——≤3.006—≤3.006≤3.006
Linear Error(ppm) — Ba———≤9.064—≤9.064
Test Range(ppm) — K0.15–1000.15–1000.15–1000.15–1000.15–1000.15–100
Test Range(ppm) — Na0.18–1000.18–1000.18–1000.18–1000.18–1000.18–100
Test Range(ppm) — Li—0.1–30——0.1–300.1–30
Test Range(ppm) — Ca——0.1–1000—0.1–10000.1–1000
Test Range(ppm) — Ba———0.1–300—0.1–300
Response Time
Common to all models<8 s
Sample Uptake
Common to all models<4 mL/min
Stability
Common to all models≤3 %(15 s), ≤15 %(6 min)
Reproducibility
Common to all models3 %
Air Compressor
Common to all modelsExternal
Printer
Common to all modelsOptional built-in thermal printer
Com
Common to all modelsUSB
Fuel
Common to all modelsLPG
Consumption
Common to all models30 W
Power Supply
Common to all modelsAC 100–240 V, 50/60 Hz
Working Conditions
Common to all modelsAmbient temperature: 10–35 °C Relative humidity: ≤85 %
External Size(W*D*H)
Common to all models425 × 310 × 437 mm
Package Size(W*D*H)
Common to all modelsMain unit: 634 × 364 × 337 mm Air compressor: 350 × 185 × 345 mm
Net Weight
Common to all models10 kg
Gross Weight
Common to all modelsMain unit: 12 kg Air compressor: 5.3 kg

MADE-TO-ORDER SUPPLY

Do you need this equipment?

Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.

The information provided will be used only to respond to your request. More privacy information