Spectroscopy

Flame Spectrophotometer BK-FP Series

BK-FP6450 / BK-FP6440 / BK-FP6431 / BK-FP6430 / BK-FP6410 / BK-FP640

Flame photometer for determining elements from the intensity of radiation emitted in a flame. It is used for routine analysis of water, soil, fertiliser, food and clinical samples; measurable elements vary by model.

Key features

  • Controlled optical measurement
  • Configurations for different spectral ranges
  • R&D and quality-control applications
Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery to the UK, all European countries, USA, Canada, Mexico and South America.

01 / Accessories

Available accessories

Included accessories

  • Oil-free air compressor
  • Regulator and tubing for LPG, air and waste liquid

Optional accessories

  • Atomiser or nebuliser
  • Printer
  • Compatible software

Final contents, accessory compatibility and availability are confirmed in the quotation for the selected model.

02 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterBK-FP6450BK-FP6440BK-FP6431BK-FP6430BK-FP6410BK-FP640
Test ElementK/Na/Li/Ca/BaK/Na/Li/CaK/Na/CaK/Na/LiK/NaK/Na
Channel Qty.543322
LOD(ppm)
Common to all modelsK · ≤0.156 · ≤0.156 · ≤0.156 · ≤0.156 · ≤0.156 · ≤0.156
LOD(ppm) (2)
Common to all modelsNa · ≤0.184 · ≤0.184 · ≤0.184 · ≤0.184 · ≤0.184 · ≤0.184
LOD(ppm) (3)
Common to all modelsLi · ≤0.1035 · ≤0.1035 · / · ≤0.1035 · / · /
LOD(ppm) (4)
Common to all modelsCa · ≤2 · ≤2 · ≤2 · / · / · /
LOD(ppm) (5)
Common to all modelsBa · ≤6.028 · / · / · / · / · /
Linear Error(ppm)
Common to all modelsK · ≤0.195 · ≤0.195 · ≤0.195 · ≤0.195 · ≤0.195 · ≤0.195
Linear Error(ppm) (2)
Common to all modelsNa · ≤0.69 · ≤0.69 · ≤0.69 · ≤0.69 · ≤0.69 · ≤0.69
Linear Error(ppm) (3)
Common to all modelsLi · ≤0.1449 · ≤0.1449 · / · ≤0.1449 · / · /
Linear Error(ppm) (4)
Common to all modelsCa · ≤3 · ≤3 · ≤3 · / · / · /
Linear Error(ppm) (5)
Common to all modelsBa · ≤9.402 · / · / · / · / · /
Test Range(ppm)
Common to all modelsK · 0.15–100 · 0.15–100 · 0.15–100 · 0.15–100 · 0.15–100 · 0.15–100
Test Range(ppm) (2)
Common to all modelsNa · 0.18–100 · 0.18–100 · 0.18–100 · 0.18–100 · 0.18–100 · 0.18–100
Test Range(ppm) (3)
Common to all modelsLi · 0.1–30 · 0.1–30 · / · 0.1–30 · / · /
Test Range(ppm) (4)
Common to all modelsCa · 0.1–1000 · 0.1–1000 · 0.1–1000 · / · / · /
Test Range(ppm) (5)
Common to all modelsBa · 0.1–300 · / · / · / · / · /
Response Time
Common to all models8 s
Sample Uptake
Common to all models<3 mL/min
Stability
Common to all models≤3 %(15 s), ≤15 %(6 min)
Reproducibility
Common to all models≤2 %
Air Compressor
Common to all modelsExternal
PrinterOptional built-in thermal printerOptional built-in thermal printerOptional built-in thermal printerOptional built-in thermal printerOptional built-in thermal printer—
ComUSBUSBUSBUSBUSB—
Fuel
Common to all modelsLPG
Power
Common to all modelsAC110/220 V, 50/60 Hz
Package Size(W*D*H)
Common to all models570 × 530 × 400 mm

MADE-TO-ORDER SUPPLY

Do you need this equipment?

Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.

The information provided will be used only to respond to your request. More privacy information