Chromatography

gas chromatograph

BK-GC908

Featuring a more expandable three-chamber design, it can accommodate five valves, seven columns, and dual-column chambers with independent temperature control. The fully upgraded electronic flow and pressure control system (EPC) boasts a pressure control accuracy of up to 001 psi, and the new temperature control system achieves a temperature control accuracy of 01 °C.

Key features

  • Configurable analytical separation
  • Selectable detectors and accessories
  • Matched to method and sample matrix
Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery to the UK, all European countries, USA, Canada, Mexico and South America.

01 / Accessories

Available accessories

Included accessories

  • FID detector
  • General chromatography workstation software
  • Capillary sampler
  • Startup toolkit

Optional accessories

  • Sample injection system
  • TCD
  • ECD
  • FPD and NPD detector
  • Audit chromatography workstation software
  • Chromatographic column
  • Nickel catalytic converter
  • Liquid autosampler
  • Headspace sampler

Final contents, accessory compatibility and availability are confirmed in the quotation for the selected model.

02 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterBK-GC908
Oven
Temperature Range
Oven (2)
Temperature Control Accuracy
Oven (3)
Temperature Program
Oven (4)
Maximum Temperature Heating Rate
Oven (5)
Temperature Control System
Selectable Detector Types
Flame Ionization Detector (FID)
Selectable Detector Types (2)
Thermal Conductivity Detector (TCD)
Selectable Detector Types (3)
Flame Photometric Detector (FPD)
Selectable Detector Types (4)
Electron Capture Detector (ECD)
Selectable Detector Types (5)
Nitrogen-phosphorus Detector (NPD)
Selectable Sample Injection Method
It can be used with standard and inert flow path split/splitless capillary injection, septum purge packed column injection, cold column injection, programmable temperature vaporization injection ports, valve injection systems, headspace injection systems, thermal desorption injection systems, etc.
Power Supply
AC220V, 50/60 Hz
Product Size (W*D*H)
670 × 580 × 500 mm
Net Weight
60 kg
Packing Size(W*D*H)
840 × 720 × 750 mm
Gross Weight
73 kg