Bioreactors

50 and 100 L biological fermentation systems

BK-BR50 / BK-BR100

The Biological Fermentation System is an advanced setup designed for the efficient cultivation of microorganisms, cells, and enzymes for various biotechnological applications. Ideal for research and food industries, this system enables controlled fermentation processes, ensuring optimal growth conditions for yeast, bacteria, and other cell types.

Key features

  • Agitation and temperature control
  • Culture-parameter monitoring
  • Configuration for process development
Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery to the UK, all European countries, USA, Canada, Mexico and South America.

01 / Accessories

Available accessories

Included accessories

  • Fermentation Tank*1
  • Air compressor*1
  • Air tank*1
  • Steam generator*1

Final contents, accessory compatibility and availability are confirmed in the quotation for the selected model.

02 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterBK-BR50BK-BR100
Tank Structure — Capacity50 L100 L
Tank Structure — Sterilization Method
Common to all modelsIn-place sterilization
Tank Structure — Design Pressure
Common to all models0.3Mpa
Tank Structure — Working Pressure
Common to all models≤0.15Mpa
Tank Structure — Inner Material
Common to all models316 stainless steel
Tank Structure — Interface
Common to all modelsAir inlet, exhaust port, temperature probe port, PH probe port, DO interface, defoaming interface, flame protection inoculation port, feeding port, discharge port, jacket upper and lower port, etc
Tank Structure — Polishing
Common to all modelsInternal Polishing Accuracy: RA0.4 External Polishing Accuracy: RA0.6
Coefficient of Charge
Common to all models60 %~80 %
Aspect Ratio
Common to all models1:2–2.5
Jacket
Common to all modelsDesign Pressure: 0.3Mpa Material: 304 stainless steel Used for temperature control and auxiliary sterilization.
Intake Filtration
Common to all modelsMaximum Ventilation: 1.5VVM, precision 0.01 µm sterilization filter
Motor — Power
Common to all models1500 W
Motor — Speed
Common to all models50–700 rpm continuous stable adjustable
Motor — Control Accuracy
Common to all models±0.5 %* Max Speed
Motor — Resolution
Common to all models1 rpm
Stirring System
Common to all modelsTop mechanical stirring system, stainless steel with special heat treatment for mixing shaft, adjustable mixing blade is adopted, with six straight blades in 1 gear and inclined blades in 1 gear pressure turbine, the three-stage pressure type efficient defoaming paddle is set up with a baffle plate, and the intake air is set up with a ring distributor, and the gas-liquid two phases are fully mixed to improve the dissolved oxygen
Sterile Air Handling System — Air Pre-filterFiltration Capacity: 0.1m³/min Accuracy: 0.1 µm Membrane FiltrationFiltration Capacity: 0.2m³/min Accuracy: 0.1 µm Membrane Filtration
Sterile Air Handling System — Air Fine FilterFiltration Capacity: 0.1m³/min Accuracy: 0.01 µm Membrane FiltrationFiltration Capacity: 0.2m³/min Accuracy: 0.01 µm Membrane Filtration
Sterile Air Handling System — Steam Filtration System
Common to all modelsStainless steel shell, PTFE filter element, membrane filtration, filtration accuracy is 5 µm.
Sterile Air Handling System — Air Decompression and Oil-water Separator
Common to all modelsReduce the air pressure from the air compressor to 0.2–0.25Mpa, with an oil-water separator to remove oil and water in the air.
Temperature Control System — Measuring Range
Common to all models0–150 °C
Temperature Control System — Control Range
Common to all modelsWater temperature in tank~65 °C
Temperature Control System — Control Accuracy
Common to all models±0.5 °C
Temperature Control System — Resolution
Common to all models0.1 °C
PH Control System — Control Mode
Common to all modelsAutomatic
PH Control System — Display Range
Common to all models0–14PH
PH Control System — Control Range
Common to all models2–12PH
PH Control System — Resolution
Common to all models0.01PH
Pressure and Flow Detection Control System
Common to all modelsφ60 surface pressure gauge indicates pipe, tank and jacket pressure, manual control tank pressure, measuring range is 0–0.4Mpa;glass rotor flow meter manually control the intake air flow;one-way check valve is added on the pipeline to prevent material back flow from polluting the filter.
DO Control System — Control Mode
Common to all modelsAutomatic
DO Control System — Display Range
Common to all models0–100 %, 0–150 %
DO Control System — Accuracy
Common to all models±0.1 %, 1 %
DO Control System — Testing Content
Common to all modelsThe DO value is detected online
Feeding System
Common to all modelsManual and automatic control, peristaltic pump flow, equipped with replenishing bottle, the program can set the amount of flow per unit time and accumulate online measurement, equipped with 1 L flow refill bottle
Defoaming System — Control Accuracy
Common to all models10–100000Ω
Defoaming System — Control Content
Common to all modelsFoam abnormal condition alarm, automatic intermittent processing
Speed Control System
Common to all modelsSpeed: 50–700 rpm±1 %, stepless frequency conversion speed regulation
Power SupplyAC220V, 50/60 Hz(Standard); AC110V, 50/60 Hz(Optional)AC380V, 50/60 Hz
Net Weight — Tank185 kg362 kg
Net Weight — Air Compressor and Steam Generator175 kg214 kg
Package Size(L*W*H) — Tank1350 × 820 × 1750 mm1520 × 820 × 2230 mm
Package Size(L*W*H) — Air Compressor and Steam Generator1350 × 1100 × 1100 mm1370 × 1170 × 1130 mm
Gross Weight — Tank210 kg392 kg
Gross Weight — Air Compressor and Steam Generator200 kg244 kg

MADE-TO-ORDER SUPPLY

Do you need this equipment?

Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.

The information provided will be used only to respond to your request. More privacy information