Atomic Absorption Spectrophotometer BK-AA4530F

BK-AA4530F

Optical instrumentation for identification and quantification in research and quality control.

Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery across mainland Portugal, Madeira, the Azores, and all European countries.

01 / Key features

Key features

  • Controlled optical measurement
  • Configurations for different spectral ranges
  • R&D and quality-control applications

02 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterBK-AA4530F
Wavelength Range
190~900nm
Spectral Bandwidth
0.1, 0.2, 0.4, 1.0 and 2.0nm
Wavelength Accuracy
≤±0.15nm
Wavelength Repeatability
≤0.04nm
Base Line Stability
≤0.002A/30min(Cu)
Characteristic Concentration
0.02μg/ml/1%(Cu)
Detection Limit
0.004μg/ml(Cu)
Preciseness
≤0.5%
Grating
1800 lines/mm
Inflamer
All-metal titanium burner
Atomizer
Effective glass atomizer
Lamp Stand
8
D2 background Calibration
When the background is 1 A, the background ability should be deducted not less than 50 times; Self absorption background deduction method
Power Supply
220V, 50Hz
Packing Size(W*D*H)mm
860*705*755(Main instrument); 545*445*1385(Accessories)
Gross Weight(kg)
105(Main instrument); 100(Accessories)
Standard Accessories
Software; Inkjet printer; Oil free air compressor; Acetylene reducing valve; Cu hollow cathode lamp; Air filter
Optional Accessories
Graphite furnace 4510GF; Hollow cathode lamp(Ag, Au, Ca, Cd, Cr, Fe, Hg, K, Au, Mg, Mn, Na, Ni, Pb, Zn, Sb, etc), Graphite tubes, Recirculating cooling water system, Hydride generator, Autosampler
Acetylene Air Burner
100mm
Ignition Dynamic Baseline Drift
≤0.006A/30min
Characteristic Concentration (2)
≤0.025μg/ml/1%(Cu)
Related Standard Deviation of the Accuracy
≤0.5%(Cu, absorbance>0.8A) (Detection limit Cu≤0.008μg/ml)
Safety System
Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner
Max. Temperature
3000°C
Max Heating Speed
≥2000°C/S
Characteristic Quantity
Cd≤0.5*10 -12 g Cu≤0.5*10 -11 g
Accuracy
Cu≤3% Cd≤3%
Safety System (2)
Over current protection, Low air pressure alarm/protection, Low cooling water flow alarm/protection
Consumption
7000W
Packing Size(W*D*H)mm (2)
740*640*700
Gross Weight(kg) (2)
90

MADE-TO-ORDER SUPPLY

Do you need this equipment?

Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.

Request a quote