Spectroscopy

Atomic Absorption Spectrophotometer

BK-AA180B

Atomic absorption spectrophotometer for detecting and quantifying metal elements in different sample types. It can use flame or graphite-furnace atomisation with lamps specific to the elements being analysed.

Key features

  • Controlled optical measurement
  • Configurations for different spectral ranges
  • R&D and quality-control applications
Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery to the UK, all European countries, USA, Canada, Mexico and South America.

01 / Accessories

Available accessories

Included accessories

  • Element-specific hollow-cathode lamps
  • Compatible software

Optional accessories

  • Hydride generator
  • Oil-free air compressor
  • Atomiser or nebuliser
  • Burner and flame accessories
  • Audit-trail software
  • Printer
  • Computer

Final contents, accessory compatibility and availability are confirmed in the quotation for the selected model.

02 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterBK-AA180B
Wavelength Range
170–900 nm
Spectral Bandwidth
0.1, 0.2, 0.4, 0.8, 1.6, 2.4 nm
Wavelength Accuracy
±0.1 nm
Wavelength Repeatability
≤0.05 nm
Detector
Photomultiplier tube detector
Baseline Stability
Drift ≤0.002Abs, noise ≤0.001Abs(Steady 30 min) Drift ≤0.002Abs, noise ≤0.001Abs(Dynamic 15 min)
Resolution
Spectral bandwidth deviation ≤0.02 nm Manganese double line valley to peak energy ratio ≤25 %
Characteristic Concentration
Flame method for Cu: ≤0.025 µg/mL/1 %
Detection Limit
Flame method for Cu: ≤0.002 µg/mL
Preciseness
Flame method for Cu: ≤0.3 %
Background Correction Ability
Deuterium lamp calibration 1.0Abs, background ≥90 times
Diffraction Grating
Groove 1800lines/mm, blaze wavelength 250 nm
Lamp Stand
8(Support simultaneous preheating of 1–4 lights)
Standard Accessory
Element lamp(Cu*1, Hg*1), software working station
Optional Accessory
Oxygen-enriched high-temperature flame, wide slit combustion head, adjustable nebulizer, hydride vapor generator, audit trailing software, oil-free air compressor, computer, printer
Power Supply
AC220V, 50/60 Hz; 110 V, 60 Hz(Standard)
External Size(W*D*H)
1080 × 480 × 560 mm
Package Size(W*D*H)
1220 × 670 × 840 mm
Net Weight
70 kg
Gross Weight
140 kg
Air-acetylene Burner
100 mm all-titanium burner
Atomization Chamber System
Integrally molded from polyphenylene sulfide
Burner System
Flame height is adjustable and lockable, with a 360° rotatable combustion seam
Gas Flow Control System
Automatic ignition/fame-out
Reading Mode
Foot pedal operation
Safety System
Emergency shutdown protection switch, automatic gas cut-off/shutdown/alarm in case of abnormal status, abnormal air pressure, ignition failure, gas leakage, abnormal flow rate, etc.
Smart Optimization
One-key operation for instrument optimization, supporting multi-task analysis
Repeat Measurement
1–99 replicates with auto-calculation of mean/SD/RSD
Print/Export Reports
Word/Excel supported
Auto-Calibration
Curve fitting, re-slope&concentration calculation, incl. standard addition method

MADE-TO-ORDER SUPPLY

Do you need this equipment?

Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.

The information provided will be used only to respond to your request. More privacy information