Cold storage

40℃ Freezer

BRF-40V318 / BRF-40V368 / BRF-40V450

-40 °C Low Temperature Freezer Two rooms design is suitable for storing multi kinds of samples that need different temperature, or some samples that need separate storage. This type of freezers has independent temperature control to help you save both room and power.

Key features

  • Monitored temperature
  • Alarms and sample protection
  • Capacity matched to inventory
Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery across mainland Portugal, Madeira, the Azores, and all European countries.

01 / Accessories

Available accessories

Included accessories

  • Test hole*2
  • USB interface

Optional accessories

  • Temperature recorder
  • RS485 interface

Final contents, accessory compatibility and availability are confirmed in the quotation for the selected model.

02 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterBRF-40V318BRF-40V368BRF-40V450
Capacity
Common to all modelsRefrigerator · 208 L · 183 L · 295 L
Capacity (2)
Common to all modelsFreezer · 110 L · 185 L · 155 L
Temp. Range
Common to all modelsRefrigerator · 2–8 °C · 2–8 °C · 2–8 °C
Temp. Range (2)
Common to all modelsFreezer · -10~-40 °C · -10~-40 °C · -10~-40 °C
Temp. Accuracy
Common to all models0.1 °C
Temp. Uniformity
Common to all modelsRefrigerator · ≤2 °C · ≤2 °C · ≤2 °C
Temp. Uniformity (2)
Common to all modelsFreezer · ≤4 °C · ≤4 °C · ≤4 °C
Temp. Stability
Common to all modelsRefrigerator · ≤3 °C · ≤3 °C · ≤3 °C
Temp. Stability (2)
Common to all modelsFreezer · ≤4 °C · ≤4 °C · ≤4 °C
Recovery Time
Common to all modelsRefrigerator · ≤15 min(Recover to 8 °C in an ambient temp. of 32 °C) · ≤15 min(Recover to 8 °C in an ambient temp. of 32 °C) · ≤15 min(Recover to 8 °C in an ambient temp. of 32 °C)
Recovery Time (2)
Common to all modelsFreezer · ≤30 min(Recover to -37 °C in an ambient temp. of 25 °C) · ≤30 min(Recover to -37 °C in an ambient temp. of 25 °C) · ≤30 min(Recover to -37 °C in an ambient temp. of 25 °C)
Cooling Time
Common to all modelsRefrigerator · ≤80 min(Cool down to 6 °C in an ambient temp. of 32 °C) · ≤80 min(Cool down to 6 °C in an ambient temp. of 32 °C) · ≤80 min(Cool down to 6 °C in an ambient temp. of 32 °C)
Cooling Time (2)
Common to all modelsFreezer · ≤3 h(Recover to -40 °C in an ambient temp. of 25 °C) · ≤3 h(Recover to -40 °C in an ambient temp. of 25 °C) · ≤3 h(Recover to -40 °C in an ambient temp. of 25 °C)
Control System
Common to all modelsMicroprocessor control
Display
Common to all modelsLED
Alarm
Common to all modelsHigh / low temperature alarm, power failure alarm(72 h), controller failure alarm, door ajar alarm
Refrigeration Type
Common to all modelsRefrigerator · Air-cooling · Air-cooling · Air-cooling
Refrigeration Type (2)
Common to all modelsFreezer · Direct-cooling · Direct-cooling · Direct-cooling
Refrigerant
Common to all modelsRefrigerator · R290/39 g · R290/25 g · R290/50 g
Refrigerant (2)
Common to all modelsFreezer · R290/46 g · R290/60 g · R290/54 g
Compressor
Common to all modelsInternational famous brand compressor /2
Condenser & Evaporator
Common to all modelsRefrigerator · Wire-on-tube Bundy tube condenser; copper tube and aluminum fin evaporator · Wire-on-tube Bundy tube condenser; Bundy tube evaporator · Wire-on-tube Bundy tube condenser; copper tube aluminum fin evaporator
Condenser & Evaporator (2)
Common to all modelsFreezer · Wire-on-tube Bundy tube condenser; built-in coil type copper tube evaporator · Copper tube aluminum fin condenser; built-in coil type copper tube evaporator · Wire-on-tube Bundy tube condenser; built-in coil type copper tube evaporator
Defrost
Common to all modelsRefrigerator · Automatic defrost · Automatic defrost · Automatic defrost
Defrost (2)
Common to all modelsFreezer · Manual defrost · Manual defrost · Manual defrost
Construction
Common to all modelsPolyurethane cyclopentane foam
Material — Internal Material
Common to all models304 stainless steel
Material — External Material
Common to all modelsSprayed steel plate
DoorOuter door: cyclopentane monolithic foam door*2 Interior door: cyclopentane monolithic foam freezer door*2Outer door: cyclopentane monolithic foam door*2 Interior door: cold plate spray door*2Outer door: cyclopentane monolithic foam door*2 Interior door: cyclopentane monolithic foam freezer door*2
Consumption460 W627 W570 W
Power SupplyAC 220 V, 50 Hz(Standard); 220 V, 60 Hz, 110 V, 60 Hz(Optional, external transformer)AC 220 V, 50 Hz(Standard); 220 V, 60 Hz, 110 V, 60 Hz(Optional, external transformer)AC 220 V, 50 Hz(Standard); 110/220 V, 60 Hz(Optional)
Casters
Common to all modelsYes
Shelf
Common to all modelsRefrigerator · 3 · 3 · 3
Shelf (2)
Common to all modelsFreezer · 1 · 1 · 1
Standard Accessory
Common to all modelsTest hole*2, USB interface
Optional Accessory
Common to all modelsTemperature recorder, RS485 interface
Internal Size (W*D*H)
Common to all modelsRefrigerator · 590 × 495 × 746 mm · 580 × 575 × 563 mm · 590 × 675 × 746 mm
Internal Size (W*D*H) (2)
Common to all modelsFreezer · 520 × 467 × 460 mm · 580 × 575 × 563 mm · 520 × 647 × 460 mm
External Size (W*D*H)741 × 631 × 1889 mm750 × 736 × 1884 mm741 × 811 × 1889 mm
Package Size (W*D*H)880 × 770 × 2090 mm890 × 880 × 2100 mm880 × 950 × 2090 mm
Net Weight132 kg153 kg147 kg
Gross Weight178 kg195 kg200 kg

MADE-TO-ORDER SUPPLY

Do you need this equipment?

Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.

The information provided will be used only to respond to your request. More privacy information