Centrifuges

Table Top High Speed Refrigerated Centrifuge

BKC-TH16RD

The instrument applies to the experiments in fields of biology, medical science, agriculture, which is the first choice for heredity gene, protein nucleic acid PCR experiment.

Key features

  • Controlled speed and centrifugal force
  • Rotors matched to the vessel
  • Benchtop and refrigerated formats
Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery across mainland Portugal, Madeira, the Azores, and all European countries.

01 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterBKC-TH16RD
Max. Speed
16500 rpm
Max. RCF
21380×g
Max. Capacity
4 × 100 mL
Motor
AC frequency conversion motor
Speed Precision
±30 rpm
Time Range
Centrifugal time:1 min~99 min59sec Continuous centrifuge: Hold
Temp Range
-20 °C~+40 °C
Temp Accuracy
±1.0 °C
Power Supply
AC220±22 V 50/60 Hz (Standard); AC110V 60 Hz (Optional)
Noise
< 55dB(A)
External Size(W*D*H)mm
350 × 662 × 367
Package Size(W*D*H)mm
440 × 900 × 530
Net Weight(kg)
50
Gross Weight(kg)
73
No. No.1
Rotor: Angle Rotor · Max Speed(rpm): 16500 · Max RCF(×g): 18400 · Capacity: 12 × 1.5/2.0 mL · Dimension of Tube (mm): Φ10 × 42
No. No.2
Rotor: Angle Rotor · Max Speed(rpm): 15000 · Max RCF(×g): 21380 · Capacity: 24 × 1.5/2.0 mL · Dimension of Tube (mm): Φ10 × 42
No. No.3
Rotor: Angle Rotor · Max Speed(rpm): 13000 · Max RCF(×g): 19080 · Capacity: 48 × 0.5 mL · Dimension of Tube (mm): Φ8 × 32
No. No.4
Rotor: Angle Rotor · Max Speed(rpm): 13000 · Max RCF(×g): 19270 · Capacity: 32 × 1.5/2.0 mL · Dimension of Tube (mm): Φ10 × 42
No. No.5
Rotor: Angle Rotor · Max Speed(rpm): 12000 · Max RCF(×g): 10100 · Capacity: 12 × 5 mL · Dimension of Tube (mm): Φ13 × 53
No. No.6
Rotor: Angle Rotor · Max Speed(rpm): 12500 · Max RCF(×g): 16060 · Capacity: 12 × 10 mL · Dimension of Tube (mm): Φ16 × 85
No. No.7
Rotor: Angle Rotor · Max Speed(rpm): 12000 · Max RCF(×g): 15130 · Capacity: 6 × 50 mL(●) · Dimension of Tube (mm): Φ29 × 106
No. No.8
Rotor: Angle Rotor · Max Speed(rpm): 12000 · Max RCF(×g): 15130 · Capacity: 6 × 50 mL(▲) · Dimension of Tube (mm): Φ29 × 116
No. No.9
Rotor: Angle Rotor · Max Speed(rpm): 10000 · Max RCF(×g): 10620 · Capacity: 4 × 100 mL · Dimension of Tube (mm): Φ38 × 119
No. No.10
Rotor: Angle Rotor · Max Speed(rpm): 12000 · Max RCF(×g): 15370 · Capacity: 8 × 15 mL(▲) · Dimension of Tube (mm): Φ17 × 121
No. No.11
Rotor: Microplate · Max Speed(rpm): 4000 · Max RCF(×g): 2000 · Capacity: 2 × 2 × 48well · Dimension of Tube (mm): Microplate
No. No.12
Rotor: Angle Rotor · Max Speed(rpm): 13000 · Max RCF(×g): 16200 · Capacity: 6 × 8 × 0.2 mL PCR · Dimension of Tube (mm): /

MADE-TO-ORDER SUPPLY

Do you need this equipment?

Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.

The information provided will be used only to respond to your request. More privacy information