ELISA & microplates

Auto ELISA Processor

BIOBASE2001

Auto ELISA Processor BIOBASE2001 is a fully automaticdetection equipment that integrates sample addition,incubation, shaking, washing, and reading. lt is widely usedin hospital laboratories, disease prevention and controlcenters, blood centers, and blood banks, animal and plantinspection and quarantine institutions, scientific researchinstitutions, university laboratories and other places.

Key features

  • Automated microplate processing
  • Assay-matched reading and washing
  • Configurations for different workloads
Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery to the UK, all European countries, USA, Canada, Mexico and South America.

01 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterBIOBASE2001
Sample&Reagent Unit — Sample Racks
6 × 20 push-pull sample rack with detection
Sample&Reagent Unit — Sample Channel
2 channels
Sample&Reagent Unit — Liquid Level Detection
Air pressure level detection, clot detection function
Sample&Reagent Unit — Tip
1000µl, 3 tip racks
Sample&Reagent Unit — Pipetting
10µl~1000µl
Sample&Reagent Unit — Pipetting Precision
100µl: CV≤1 %, Accuracy≤2.5 % 1000µl: CV≤0.5 %, Accuracy≤1 %
Sample&Reagent Unit — Reagent Position
4 reagent racks, reagent tanks with detection
Washing Unit — Washer
1 unit
Washing Unit — Washing Head
16-channel(32-pin), double row cleaning, hanging installation, with leakage recovery
Washing Unit — Injection Uniformity
CV<1.5 %
Washing Unit — Washing Residual
<1µl
Reading Unit — Reading Channels
8 independent photometric channels
Reading Unit — Linear Range
0.000–3.000Abs
Reading Unit — Repeatability
CV≤1.0 %
Reading Unit — Stability
≤±0.003Abs
Reading Unit — Optical Filters
4 standard filters(405, 450, 492, 630 nm); Total 10 filters positions
Reading Unit — Reading Accuracy
≤±0.02Abs from 0.0 to 1.0OD ≤±0.03Abs from 1.0 to 2.0OD
Reading Unit — Sensitivity
≥0.01 mg/L
Reading Unit — Channel Difference
≤0.02Abs
Incubation Unit — Incubators
8 shaking incubators
Incubation Unit — Cover Positions
1(8 covers)
Incubation Unit — Heating Method
Dry heating with cover
Incubation Unit — Shaking Function
Horizontal circular oscillation, 1–3 levels adjustable, amplitude 2.5 mm
Incubation Unit — Temperature Range
RT to 60 °C
Incubation Unit — Temperature Uniformity
0.5 °C
Incubation Unit — Temperature Fluctuation
±0.5 °C
Data Management — Software
Above Windows 7 system
Data Management — LIS System
Bi-direction, support HL7 protocol
Data Management — Results
Absorbance and results reviewable by software
Data Management — Printer
External optional
Data Management — Built-in Scanner
Optional
Other Function — Biosafety Protection
Optional (Negative pressure working zone, HEPA filter)
Other Function — Disinfection
UV lamp
Other Function — Lighting
LED
Other Function — IAP Function
Firmware can be upgraded online at any time
Working Condition — Power Supply
AC220V±10 %, 50/60 Hz(Standard); 110 V±10 %, 60 Hz(Optional)
Working Condition — Temperature
10–40 °C
Working Condition — Humidity
30–80 %
Size&Weight — External Size(W*D*H)
Machine: 1273 × 750 × 1650 mm Base Stand: 1273 × 750 × 777 mm
Size&Weight — Net Weight
Machine: 226 kg · Base Stand: 98 kg
Size&Weight — Package Size(W*D*H)mm
Machine: 1445 × 920 × 1130 mm Base Stand: 1445 × 920 × 1005 mm Accessories: 1065 × 895 × 510 mm
Size&Weight — Gross Weight(kg)
Machine: 300 kg Base Stand: 172 kg Accessories: 83 kg

MADE-TO-ORDER SUPPLY

Do you need this equipment?

Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.

The information provided will be used only to respond to your request. More privacy information