Centrifuges

Table Top Low Speed Large Capacity Centrifuge

BKC-TL5C

BKC-TL5C is used for rapid separation of serum, plasma and other body fluids.

Key features

  • Controlled speed and centrifugal force
  • Rotors matched to the vessel
  • Benchtop and refrigerated formats
Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery to the UK, all European countries, USA, Canada, Mexico and South America.

01 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterBKC-TL5C
Max. Speed
5000 rpm
Max. RCF
3962xg
Max. Capacity
4 × 500 mL
Speed Precision
±10 rpm
Time Range
1 s~99h59min/Continuous/Short-span
Power Supply
Standard: AC220V, 50/60 Hz Optional: AC110V, 50/60 Hz
Noise
≤65dB(A)
External Size(L*W*H)
500 × 620 × 410 mm
Package Size(L*W*H)
620 × 740 × 710 mm
Net Weight
56 kg
Gross Weight
80 kg(220 V), 85 kg(110 V)
Type Swing Rotor
NO. ·: 5M00024 · Volume ·: 48 × 2/3/4/5/7 mL blood collection tube · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 2952 · Adapters ·: /
Type Swing Rotor (2)
NO. ·: 5M00025 · Volume ·: 48 × 5/7 mL blood collection tube · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 2952 · Adapters ·: 2/3/4 mL blood collection tube
Type Swing Rotor (3)
NO. ·: 5M00026 · Volume ·: 72 × 2/3/4/5/7 mL blood collection tube · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 2808 · Adapters ·: /
Type Swing Rotor (4)
NO. ·: 5M00052 · Volume ·: 80 × 2/3/4/5/7 mL blood collection tube · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 2808 · Adapters ·: /
Type Swing Rotor (5)
NO. ·: 5M00027 · Volume ·: 96 × 2/3/4/5/7 mL blood collection tube · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 3104 · Adapters ·: /
Type Swing Rotor (6)
NO. ·: 5M00029 · Volume ·: 16 × 10/15 mL · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 2957 · Adapters ·: 2/3/4 mL blood collection tube, 5/7 mL blood collection tube, 15 mL(▲)
Type Swing Rotor (7)
NO. ·: 5M00030 · Volume ·: 24 × 10/15 mL · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 2957 · Adapters ·: 2/3/4 mL blood collection tube, 5/7 mL blood collection tube, 15 mL(▲)
Type Swing Rotor (8)
NO. ·: 5M00031 · Volume ·: 32 × 10/15 mL · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 2952 · Adapters ·: 2/3/4 mL blood collection tube, 5/7 mL blood collection tube, 15 mL(▲)
Type Swing Rotor (9)
NO. ·: 5M00080 · Volume ·: 48 × 15 mL · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 3282 · Adapters ·: /
Type Swing Rotor (10)
NO. ·: 5M00032 · Volume ·: 4 × 50 mL · Max. Speed(r/min) ·: 4500 · Max. RCF(xg) ·: 3962 · Adapters ·: 50 mL(▲), 20 mL, 15 mL, 10 mL, 5 mL, 1.5/2 mL
Type Swing Rotor (11)
NO. ·: 5M00033 · Volume ·: 8 × 50 mL · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 2952 · Adapters ·: 50 mL(▲), 20 mL, 15 mL, 10 mL, 5 mL, 1.5/2 mL
Type Swing Rotor (12)
NO. ·: 5M00034 · Volume ·: 4 × 100 mL · Max. Speed(r/min) ·: 4500 · Max. RCF(xg) ·: 3962 · Adapters ·: 16 × 2/3/4 mL blood collection tube, 16 × 5/7 mL blood collection tube
Type Swing Rotor (13)
NO. ·: 5M00036 · Volume ·: 8 × 100 mL · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 3077 · Adapters ·: 32 × 2/3/4 mL blood collection tube, 32 × 5/7 mL blood collection tube
Type Swing Rotor (14)
NO. ·: 5M00037 · Volume ·: 4 × 250 mL(▲) · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 3578 · Adapters ·: /
Type Swing Rotor (15)
NO. ·: 5M00038 · Volume ·: 4 × 250 mL(flat bottom) · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 2780 · Adapters ·: 48 × 1.5/2 mL, 40 × 2/3/4/5/7 mL blood collection tube, 48 × 2/3/4/5/7 mL blood collection tube, 24 × 10 mL(▲), 28 × 10 mL, 20 × 15 mL, 4 × 50 mL(▲), 8 × 50 mL(●), 4 × 100 mL
Type Swing Rotor (16)
NO. ·: 5M00053 · Volume ·: 4 × 250 mL(biosafety) · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 3041 · Adapters ·: 48 × 1.5/2 mL, 40 × 2/3/4/5/7 mL blood collection tube, 48 × 2/3/4/5/7 mL blood collection tube, 24 × 10 mL(▲), 28 × 10 mL, 20 × 15 mL, 4 × 50 mL(▲), 8 × 50 mL(●), 4 × 100 mL
Type Swing Rotor (17)
NO. ·: 5M00058 · Volume ·: 4 × 300 mL · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 3220 · Adapters ·: /
Type Swing Rotor (18)
NO. ·: 5M00039 · Volume ·: 4 × 500 mL(flat bottom) · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 3130 · Adapters ·: 48 × 2/3/4/5/7 mL blood collection tube, 64 × 2/3/4/5/7 mL blood collection tube, 36 × 10 mL(●), 36 × 10 mL(▲), 36 × 15 mL(●), 36 × 15 mL(▲), 12 × 50 mL(●), 12 × 50 mL(▲), 16 × 50 mL(●), 16 × 50 mL(▲), 48 × 15 mL(▲), 4 × 250 mL, 32 × 15 mL(▲), 48 × 10 mL(●)
Type Swing Rotor (19)
NO. ·: 5M00054 · Volume ·: 4 × 500 mL(biosafety) · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 3399 · Adapters ·: 48 × 2/3/4/5/7 mL blood collection tube, 64 × 2/3/4/5/7 mL blood collection tube, 36 × 10 mL(●), 36 × 10 mL(▲), 36 × 15 mL(●), 36 × 15 mL(▲), 12 × 50 mL(●), 12 × 50 mL(▲), 16 × 50 mL(●), 16 × 50 mL(▲), 48 × 15 mL(▲), 4 × 250 mL, 32 × 15 mL(▲), 48 × 10 mL(●)
Type Swing Rotor (20)
NO. ·: 5M00040 · Volume ·: 4 × 500 mL(▲) · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 3578 · Adapters ·: /
Type Auto Uncapped Swing Rotor
NO. ·: 5M00047 · Volume ·: 80 × 2/3/4/5/7 mL blood collection tube(auto uncapped) · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 3220 · Adapters ·: /
Type Microplate Rotor
NO. ·: 5M00045 · Volume ·: 2 × 2 × 96well · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 2361 · Adapters ·: /
Type Microplate Rotor (2)
NO. ·: 5M00043 · Volume ·: 4 × 2 × 96well · Max. Speed(r/min) ·: 4000 · Max. RCF(xg) ·: 2987 · Adapters ·: /
Type Angle Rotor
NO. ·: 5M00072 · Volume ·: 12 × 20 mL · Max. Speed(r/min) ·: 5000 · Max. RCF(xg) ·: 3516 · Adapters ·: 15 mL, 10 mL, 5 mL, 1.5/2 mL
Type Angle Rotor (2)
NO. ·: 5M00073 · Volume ·: 12 × 15 mL · Max. Speed(r/min) ·: 5000 · Max. RCF(xg) ·: 3354 · Adapters ·: 1.5/2 mL, 2/3/4 mL blood collection tube
Type Angle Rotor (3)
NO. ·: 5M00074 · Volume ·: 8 × 15/20 mL · Max. Speed(r/min) ·: 5000 · Max. RCF(xg) ·: 2655 · Adapters ·: 1.5/2 mL, 2/3/4 mL blood collection tube
Type Angle Rotor (4)
NO. ·: 5M00069 · Volume ·: 24 × 10/15 mL · Max. Speed(r/min) ·: 5000 · Max. RCF(xg) ·: 3494 · Adapters ·: 2/3/4 mL blood collection tube, 5/7 mL blood collection tube, 15 mL(▲)
Type Angle Rotor (5)
NO. ·: 5M00075 · Volume ·: 24 × 10 mL · Max. Speed(r/min) ·: 5000 · Max. RCF(xg) ·: 3354 · Adapters ·: 1.5/2 mL, 2/3/4 mL blood collection tube
Type Angle Rotor (6)
NO. ·: 5M00076 · Volume ·: 18 × 10 mL · Max. Speed(r/min) ·: 5000 · Max. RCF(xg) ·: 3354 · Adapters ·: 1.5/2 mL, 2/3/4 mL blood collection tube
Type Angle Rotor (7)
NO. ·: 5M00077 · Volume ·: 12 × 10 mL · Max. Speed(r/min) ·: 5000 · Max. RCF(xg) ·: 3354 · Adapters ·: 1.5/2 mL, 2/3/4 mL blood collection tube
Type Angle Rotor (8)
NO. ·: 5M00084 · Volume ·: 6 × 50 mL · Max. Speed(r/min) ·: 5000 · Max. RCF(xg) ·: 2711 · Adapters ·: 50 mL(▲), 20 mL, 15 mL, 10 mL, 5 mL, 1.5/2 mL

MADE-TO-ORDER SUPPLY

Do you need this equipment?

Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.

The information provided will be used only to respond to your request. More privacy information