Laboratory analysis

Portable Water Analyzer

BK-WA1000

The instrument utilizes narrowband interference technology and high precision optical filtering to filter out a large amount of stray light, thereby enhancing the purity of the light entering the system, avoiding the impact of instrument noise and drift, and improving the stability of the instrument.

Key features

  • Digital measurement
  • Method matched to the parameter
  • Repeatable results and data capture
Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery across mainland Portugal, Madeira, the Azores, and all European countries.

01 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterBK-WA1000
Display Error
≤8 %
Repeatability
≤±3 %
Optical Stability
≤0.001 A/10 min
Light Source Life
100,000 hours
Measurement Time
10 min
Number of Curves
200 can be set
Data Storage
5000 pieces can be stored
Wavelength Range
380–800 nm
Display
7 inch color touch screen/5.6-inch omron button integrated screen
Printer
Built-in thermal printer
Reading Cuvette
Cuvette /Colorimetric tube
pH — Range
-1.99–19.99pH
pH — Resolution
0.1/0.01
pH — Accuracy
±0.01pH
pH — Stability
±0.01 pH/3 h
ORP
Range · -2000 mV~0–2000 mV
ORP (2)
Resolution · 1 mV
ORP (3)
Accuracy · ±0.1 % FSmV
Conductivity
Range · (0.00–20.00)µS/cm (20.0–200.0)µS/cm (200–2000)µS/cm (2.00–20.00)mS/cm (20.0–200.0)mS/cm (200–2000)mS/cm(K=10)
Conductivity (2)
Resolution · 0.01/0.1/1µS/cm, 0.01/0.1/1 mS/cm
Conductivity (3)
Accuracy · ±1.0 % F.S.
Conductivity (4)
Reference Temperature · 25 °C/20 °C/18 °C
Conductivity (5)
Cell Constant · K=0.1, 1, 10
TDS
Range · (0–100)g/L
TDS (2)
Resolution · 0.01/0.1/1µS/cm, 0.01/0.1/1 mS/cm
TDS (3)
Accuracy · ±1.0 % F.S.
Salinity
Range · (0–100)ppt
Salinity (2)
Resolution · 0.01/0.1/1µS/cm, 0.01/0.1/1 mS/cm
Salinity (3)
Accuracy · ±1.0 % F.S.
Resistivity
Range · (0–100)MΩ·cm
Resistivity (2)
Resolution · 0.01/0.1/1µS/cm, 0.01/0.1/1 mS/cm
Resistivity (3)
Accuracy · ±1.0 % F.S.
DO
Range · (0–20.00)mg/L(ppm), (0–200.0)%
DO (2)
Resolution · 0.1/0.01 mg/L(ppm), 1/0.1 %
DO (3)
Accuracy · ±0.10 mg/L
DO (4)
Stability · (±0.07 mg/L)/1 h
DO (5)
Barometric Pressure Correction · (0–200)kPa, manual
DO (6)
Salinity Correction · (0–45)ppt, manual
Other Specifications
Temperature Compensation · 0–100 °C/32–212°F, manual or automatic
Other Specifications (2)
Memory · 500 data sets, USB communication interface, wireless Bluetooth interface
Other Specifications (3)
Power Requirements · AC220V±10 %/50 Hz
Other Specifications (4)
Dimension · 525 × 200 × 390 mm
Other Specifications (5)
Net Weight · 17 kg
Other Specifications (6)
Packing Size · 695 × 365 × 500 mm
Other Specifications (7)
Gross Weight · 21 kg

MADE-TO-ORDER SUPPLY

Do you need this equipment?

Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.

The information provided will be used only to respond to your request. More privacy information