Laboratory analysis

Benchtop pH/ORP/Ion Meter

PH-A120-CN PH-A120-UK / PH-A130-CN PH-A130-UK / PH-A131

1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers Automatic electrode diagnosis shows the pH slope and offset

Key features

  • Digital measurement
  • Method matched to the parameter
  • Repeatable results and data capture
Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery across mainland Portugal, Madeira, the Azores, and all European countries.

01 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterPH-A120-CN PH-A120-UKPH-A130-CN PH-A130-UKPH-A131
PH
Common to all modelsRange · -2.000–20.000pH · • · • · —
PH (2)
Common to all modelsResolution · 0.001, 0.01, selectable · • · • · —
PH (3)
Common to all modelsAccuracy · ±0.002pH · • · • · —
PH (4)
Common to all modelsCalibration Points · 1 to 5 points · • · • · —
PH (5)
Common to all modelspH Buffer Options · USA, NIST, DIN, 5 custom buffers · • · • · —
ORP(optional)
Common to all modelsmV Range · ±2000.0 mV · • · • · •
ORP(optional) (2)
Common to all modelsRelative mV Range · ±2000.0 mV · • · • · —
ORP(optional) (3)
Common to all modelsResolution · 0.1 mV · • · • · •
ORP(optional) (4)
Common to all modelsAccuracy · ±0.2 mV · • · • · •
ORP(optional) (5)
Common to all modelsCalibration Points · 1 point · • · • · —
Ion
Common to all modelsRange · 0.001–30000 (depending on the range of ISE) · — · • · •
Ion (2)
Common to all modelsResolution · 0.001, 0.01, 0.1, 1 · — · • · •
Ion (3)
Common to all modelsAccuracy · ±0.5 % F.S. (monovalent), ±1 % F.S. (divalent) · — · • · •
Ion (4)
Common to all modelsMeasurement Units · ppm, mg/L, mol/L, mmol/L · — · • · •
Ion (5)
Common to all modelsCalibration Points · 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) · — · • · •
Ion (6)
Common to all modelsMeasurement Methods · Direct reading, known addition, known subtraction, sample addition, sample subtraction · — · • · •
Ion (7)
Common to all modelsElectrode Management · 1 to 3 electrodes · — · • · •
Water Hardness
Common to all modelsRange · 0.05–200mmol/L, 0–1122°dH, 0–1404°e, 0–2000°fH, 0–8000 mg/L (Ca2+) · — · • · •
Water Hardness (2)
Common to all modelsResolution · 0.001, 0.01, 0.1, 1 · — · • · •
Water Hardness (3)
Common to all modelsAccuracy · ±1 % F.S. · — · • · •
Water Hardness (4)
Common to all modelsCalibration Points · 2 to 5 points (0.01, 0.1, 1, 10, 100mmol/L) · — · • · •
Temperature
Common to all modelsRange · 0–105 °C/32–221°F · • · • · •
Temperature (2)
Common to all modelsResolution · 0.1 °C/0.1°F · • · • · •
Temperature (3)
Common to all modelsAccuracy · ±0.5 °C/±0.9°F · • · • · •
Temperature (4)
Common to all modelsOffset Calibration · 1 point, reading ±10 °C · • · • · •
Other Specifications
Common to all modelsTemperature Compensation · 0–100 °C, manual or automatic · • · • · •
Other Specifications (2)
Common to all modelsSolution Temperature Coefficient · 25 °C · • · • · —
Other Specifications (3)
Common to all modelsStability Criteria · Standard or high-accuracy · • · • · •
Other Specifications (4)
Common to all modelsCalibration Due Alarm · 1 to 31 days or off · • · • · •
Other Specifications (5)
Common to all modelsInterval Readings · 10, 30, 60 seconds, 10, 30 minutes or off · • · • · •
Other Specifications (6)
Common to all modelsPassword Protection · 4 digits · • · • · •
Other Specifications (7)
Common to all modelsMemory · 1000 data sets · • · • · •
Other Specifications (8)
Common to all modelsCommunication Interface · USB · • · • · •
Other Specifications (9)
Common to all modelsConnector · BNC, 3.5 mm jack socket · • · • · •
Other Specifications (10)
Common to all modelsDisplay · 7 inches TFT LCD · • · • · •
Other Specifications (11)
Common to all modelsPower Supply · Standard: 220 V 50/60 Hz; Optional: 110 V, 50/60 Hz; DC12V power adapter · • · • · •
Other Specifications (12)
Common to all modelsOuter Dimensions · 240 × 220 × 80 mm · 240 × 220 × 80 mm · 240 × 220 × 80 mm
Other Specifications (13)
Common to all modelsNet Weight · 1.7 kg · 1.7 kg · 1.7 kg
Other Specifications (14)
Common to all modelsPacking Size · 320 × 250 × 200 mm · 320 × 250 × 200 mm · 320 × 250 × 200 mm
Other Specifications (15)
Common to all modelsGross Weight · 1.8 kg · 1.8 kg · 1.8 kg

MADE-TO-ORDER SUPPLY

Do you need this equipment?

Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.

The information provided will be used only to respond to your request. More privacy information