Laboratory analysis

Benchtop Conductivity/TDS/Salinity/Resistivity Meter

PH-950

The Benchtop Conductivity/TDS/Salinity/Resistivity Meter is a high-precision analytical instrument designed for accurate measurement of water quality parameters in laboratory and industrial environments.

Key features

  • Digital measurement
  • Method matched to the parameter
  • Repeatable results and data capture
Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery to the UK, all European countries, USA, Canada, Mexico and South America.

01 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterPH-950
Conductivity
Range · Standard · CON-1: 2µs/cm~20000µs/cm
Conductivity (2)
Range · Optional · CON-0.01: 0.01µs/cm~20µs/cm CON-0.1: 0.1µs/cm~200µs/cm CON-10: 100µs/cm~200ms/cm
Conductivity (3)
Accuracy · ±0.5 % F.S.
Conductivity (4)
Resolution · 0.001, 0.01, 0.1, 1
Conductivity (5)
Calibration Points · 1 to 5 points
Conductivity (6)
Calibration Solutions · 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
TDS
Range · 0–10.00, 100.0, 1000ppm, 10.00, 200.0ppt
TDS (2)
Accuracy · ±1 %F.S.
TDS (3)
Resolution · 0.01, 0.1, 1
Salinity
TDS Factor · 0.1–1.0(default 0.5)
Salinity (2)
Range · 0.00–42.00psu, 0.00–80.00ppt
Salinity (3)
Accuracy · ±1 %F.S.
Resistivity
Resolution · 0.01, 0.1
Resistivity (2)
Range · 0.00–20.00MΩ
Resistivity (3)
Accuracy · ±1 % F.S.
Temperature — Resolution
0.01
Temperature — Range
0–105 °C/32–221°F
Temperature — Accuracy
±0.5 °C/±0.9°F
Other Specifications
Resolution · 0.1 °C/0.1°F
Other Specifications (2)
Offset Calibration · 1 point, reading ±10 °C
Other Specifications (3)
Temperature Compensation · 0–100 °C, manual or automatic
Other Specifications (4)
Temperature Coefficient · Linear(0.0–10.0 %/°C), non-linear, pure water
Other Specifications (5)
Reference Temperature · 20/25 °C
Other Specifications (6)
Cell Constant · K=0.1, 1, 10
Other Specifications (7)
Stability Criteria · Low or high
Other Specifications (8)
Calibration Due Alarm · 1 to 31 days or off
Other Specifications (9)
Calibration Factor Display · Yes
Other Specifications (10)
Hold Function · Manual or auto-endpoint
Other Specifications (11)
Memory · 500 data sets
Other Specifications (12)
Communication Interface · USB
Other Specifications (13)
Connector · 6-pin mini-DIN, 3.5 mm jack socket
Other Specifications (14)
Display · Custom LCD(125 × 100 mm)
Other Specifications (15)
Power Requirements · DC5V power adapter
Other Specifications (16)
Dimensions(mm) · 210 × 188 × 60 mm
Other Specifications (17)
Weight(kg) · 1.5 kg
Other Specifications (18)
Package Size(W*D*H)mm · 310 × 240 × 180 mm
Other Specifications (19)
Gross Weight(kg) · 1.7 kg

MADE-TO-ORDER SUPPLY

Do you need this equipment?

Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.

The information provided will be used only to respond to your request. More privacy information