Key features

  • Digital measurement
  • Method matched to the parameter
  • Repeatable results and data capture

02 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterBK-EC3ABK-EC3B
Conductivity
Common to all modelsRange · 0.00μS/cm~200mS/cm · 0.00μS/cm~200mS/cm
Conductivity (2)
Common to all modelsResolution · 0.01μS/cm, selectable according to the range · 0.01μS/cm, selectable according to the range
Conductivity (3)
Common to all modelsElectronic Unit Repeatability · 0.33%FS · 0.33%FS
Conductivity (4)
Common to all modelsInstrument Repeatability · 0.70%FS · 0.70%FS
Conductivity (5)
Common to all modelsElectronic Unit Reference Error · ±1.0%FS · ±1.0%FS
Conductivity (6)
Common to all modelsInstrument Reference Error · ±1.5%FS · ±1.5%FS
TDS
Common to all modelsRange · 0.00mg/L~100g/L · 0.00mg/L~100g/L
TDS (2)
Common to all modelsResolution · 0.01mg/L, selectable according to the range · 0.01mg/L, selectable according to the range
TDS (3)
Common to all modelsElectronic Unit Reference Error · ±1.0%FS · ±1.0%FS
Resistivity
Common to all modelsRange · 5.00Ω·cm~20.0MΩ·cm · 5.00Ω·cm~20.0MΩ·cm
Resistivity (2)
Common to all modelsResolution · 0.01Ω·cm, selectable according to the range · 0.01Ω·cm, selectable according to the range
Resistivity (3)
Common to all modelsElectronic Unit Reference Error · ±1.0%FS · ±1.0%FS
Salinity
Common to all modelsRange · 0~100ppt · 0~100ppt
Salinity (2)
Common to all modelsResolution · 0.01ppt · 0.01ppt
Salinity (3)
Common to all modelsAccuracy · ±0.2% · ±0.2%
Temperature — Range/-5.0~110.0℃
Temperature — Resolution/0.1℃
Temperature — Accuracy/±0.4℃(0.0~60.0℃) ±1.0℃(Other ranges)
Temperature Compensation Range-5.0~110.0℃, manual-5.0~110.0℃, manual/automatic
Power Supply
Common to all modelsAC100~240V, 50/60Hz
External Size(W*D*H)
Common to all models250*190*71mm
Package Size(W*D*H)
Common to all models300*310*300mm
Net Weight
Common to all models1.5kg
Gross Weight
Common to all models2.2kg