Cold storage

25℃ Freezer Combined Refrigerator and Freezer

BRF-25V300 / BRF-25V318 / BRF-25V368 / BRF-25V450

The -25 °C freezer can be used for scientific research, low temperature test of special materials, low temperature test of frozen plasma, biological materials, vaccines, biological products, etc. Applicable to scientific research institutes, electronics industry, chemical industry, hospitals, university laboratories, etc.

Key features

  • Monitored temperature
  • Alarms and sample protection
  • Capacity matched to inventory
Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery to the UK, all European countries, USA, Canada, Mexico and South America.

01 / Accessories

Available accessories

Included accessories

  • Test hole*2
  • USB interface

Optional accessories

  • Temperature recorder
  • Remote alarm
  • RS485 interface

Final contents, accessory compatibility and availability are confirmed in the quotation for the selected model.

02 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterBRF-25V300BRF-25V318BRF-25V368BRF-25V450
Capacity
Common to all modelsRefrigerator · 174 L · 208 L · 183 L · 295 L
Capacity (2)
Common to all modelsFreezer · 126 L · 110 L · 185 L · 155 L
Temp. Range
Common to all modelsRefrigerator · 2–8 °C · 2–8 °C · 2–8 °C · 2–8 °C
Temp. Range (2)
Common to all modelsFreezer · -10~-25 °C · -10~-25 °C · -10~-25 °C · -10~-25 °C
Temp. Accuracy
Common to all models0.1 °C
Temp. Uniformity
Common to all modelsRefrigerator · ≤2 °C · · ≤2 °C · · ≤2 °C · · ≤2 °C ·
Temp. Uniformity (2)
Common to all modelsFreezer · ≤3 °C · ≤3 °C · ≤3 °C · ≤3 °C
Temp. Stability
Common to all models≤3 °C
Recovery Time ·
Common to all modelsRefrigerator · ≤15 min(Recover to 8 °C in an ambient temp. of 32 °C) · · ≤15 min(Recover to 8 °C in an ambient temp. of 32 °C) · · ≤15 min(Recover to 8 °C in an ambient temp. of 32 °C) · · ≤15 min(Recover to 8 °C in an ambient temp. of 32 °C) ·
Recovery Time · (2)
Common to all modelsFreezer · ≤15 min(Recover to -22 °C in an ambient temp. of 25 °C) · ≤15 min(Recover to -22 °C in an ambient temp. of 25 °C) · ≤15 min(Recover to -22 °C in an ambient temp. of 25 °C) · ≤15 min(Recover to -22 °C in an ambient temp. of 25 °C)
Cooling Time ·
Common to all modelsRefrigerator · ≤80 min(Cool down to 6 °C in an ambient temp. of 32 °C) · · ≤80 min(Cool down to 6 °C in an ambient temp. of 32 °C) · · ≤80 min(Cool down to 6 °C in an ambient temp. of 32 °C) · · ≤80 min(Cool down to 6 °C in an ambient temp. of 32 °C) ·
Cooling Time · (2)
Common to all modelsFreezer · ≤1.5 h(Recover to -25 °C in an ambient temp. of 25 °C) · ≤1.5 h(Recover to -25 °C in an ambient temp. of 25 °C) · ≤1.5 h(Recover to -25 °C in an ambient temp. of 25 °C) · ≤1.5 h(Recover to -25 °C in an ambient temp. of 25 °C)
Control System
Common to all modelsMicroprocessor control
Display
Common to all modelsLED
AlarmHigh / low temperature alarm, power failure alarm(24 h), controller failure alarm, door ajar alarmHigh / low temperature alarm, power failure alarm(72 h), controller failure alarm, door ajar alarmHigh / low temperature alarm, power failure alarm(72 h), controller failure alarm, door ajar alarmHigh / low temperature alarm, power failure alarm(72 h), controller failure alarm, door ajar alarm
Refrigeration Type
Common to all modelsRefrigerator · Air-cooling · Air-cooling · Air-cooling · Air-cooling
Refrigeration Type (2)
Common to all modelsFreezer · Direct-cooling · Direct-cooling · Direct-cooling · Direct-cooling
Refrigerant
Common to all modelsRefrigerator · R600a/28 g · R290/39 g · R290/25 g · R290/50 g
Refrigerant (2)
Common to all modelsFreezer · R600a/48 g · R290/55 g · R290/40 g · R290/57 g
Compressor
Common to all modelsInternational famous brand compressor /2
Condenser & Evaporator
Common to all modelsRefrigerator · Side-panel type Bundy tube condenser; wall-mounted/wire-on-tube Bundy tube evaporator · Wire-on-tube Bundy tube condenser; copper tube aluminum fin evaporator · Wire-on-tube Bundy tube condenser; Bundy tube evaporator · Wire-on-tube Bundy tube condenser; Bundy tube evaporator
Condenser & Evaporator (2)
Common to all modelsRefrigerator · Side-panel type Bundy tube condenser; wall-mounted/wire-on-tube Bundy tube evaporator · Wire-on-tube Bundy tube condenser; built-in coil type copper tube evaporator(合并了) · Wire-on-tube Bundy tube condenser; built-in coil type copper tube evaporator(合并了) · Wire-on-tube Bundy tube condenser; built-in coil type copper tube evaporator(合并了)
Condenser & Evaporator (3)
Common to all modelsFreezer · Side-panel type Bundy tube condenser; wall-mounted/wire-on-tube Bundy tube evaporator · Wire-on-tube Bundy tube condenser; built-in coil type copper tube evaporator(合并了) · Wire-on-tube Bundy tube condenser; built-in coil type copper tube evaporator(合并了) · Wire-on-tube Bundy tube condenser; built-in coil type copper tube evaporator(合并了)
Defrost
Common to all modelsRefrigerator · Automatic defrost · Automatic defrost · Automatic defrost · Automatic defrost
Defrost (2)
Common to all modelsFreezer · Manual defrost · Manual defrost · Manual defrost · Manual defrost
Construction
Common to all modelsPolyurethane cyclopentane foam
Material ·
Common to all modelsInternal Material · HIPS · 304 stainless steel · 304 stainless steel · 304 stainless steel
Material · (2)
Common to all modelsExternal Material · Precoated steel plate · Sprayed steel plate · Sprayed steel plate · Sprayed steel plate
DoorOuter door: cyclopentane monolithic foam door*2 Interior door: /Outer door: cyclopentane monolithic foam door*2 Interior door: freezer door optionalOuter door: cyclopentane monolithic foam door*2 Interior door: freezer door optionalOuter door: cyclopentane monolithic foam door*2 Interior door: freezer door optional
Consumption160 W390 W594 W410 W
Power SupplyAC 220 V, 50 Hz(Standard); 110/220 V, 60 Hz(Optional)AC 220 V, 50 Hz(Standard); 220 V, 60 Hz, 110 V, 60 Hz(Optional, external transformer)AC 220 V, 50 Hz(Standard); 220 V, 60 Hz, 110 V, 60 Hz(Optional, external transformer)AC 220 V, 50 Hz(Standard); 220 V, 60 Hz, 110 V, 60 Hz(Optional, external transformer)
CastersNoYesYesYes
Shelf
Common to all modelsRefrigerator · 3 · 3 · 3 · 3
Shelf (2)
Common to all modelsFreezer · 3(PS drawer) · 1 · 1 · 1
Standard Accessory
Common to all modelsTest hole*2, USB interface
Optional AccessoryTemperature recorder, remote alarmTemperature recorder, remote alarmTemperature recorder, RS485 interfaceTemperature recorder, RS485 interface
Internal Size (W*D*H)
Common to all modelsRefrigerator · 510 × 480 × 720 mm · 590 × 495 × 746 mm · 580 × 575 × 563 mm · 590 × 675 × 746 mm
Internal Size (W*D*H) (2)
Common to all modelsFreezer · 420 × 450 × 670 mm · 520 × 467 × 460 mm · 580 × 575 × 563 mm · 520 × 647 × 460 mm
External Size (W*D*H)595 × 600 × 1700 mm741 × 631 × 1889 mm750 × 736 × 1884 mm741 × 811 × 1889 mm

MADE-TO-ORDER SUPPLY

Do you need this equipment?

Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.